Company Profile Products List Contact Us CHINESE HOME
Karl-Fischer Moisture Meter
AQUAMICRON
AQUAMICRON
Karl-Fischer Moisture Meter
Automatic Titration Model
Total Sulfur Analyzer
Total Chlorine Analyzer
Total Nitrogen Analyzer
Total Sulfur/Chlorine Analyzer
Total Sulfur/Nitrogen Analyzer
Total Sulfur/Chlorine/Nitrogen Analyzer
Adsorbable Organic Halogen Analyzer
Total Organic Carbon Analyzer
Automatic Quick Furnace model
Automatic Quick Furnace model
Resistivity Meter Series
Resistivity Meter Series
Resistivity Meter Series
Powder Resistivity Measuring System
Measures Resistivity
Integrating-Sphere Turbid Meter
Thickness Tester model TH-11 with optional printer
Special electrolyte device
MX-50(A&D)
Precision Oven
Differential Scanning Calorimeter
Transient Plane Source
  Classification >>  Karl-Fischer Moisture Meter >> Karl-Fisher Volumetric titration >> 
    Related Product >> 
  Karl-Fischer Volumetric titration Frequency 7376
Model No: CA-310 Volumetric
Product Name: Karl-Fischer Volumetric titration
Maker: Nittoseiko Analytech
Distributor: South&North International Co., Ltd.
RelateDate

Specification

 

CA-310《Volumetric》

Highly scalable with maximum 4-channel simultaneous measurement controlled by wide color touch screen.
The system can be applied for a multiude of applications, from simple batch measurement to full automation.
Progressive moisture meter, CA-310 is active in wide range of applications, pharmaceuticlas, foods, oils etc.

CA-310

 

 CA-310 Specifications 《Volumetric Moisture Meter》


Measurement method:   Volumetric Karl-Fischer Titration,
                                        Up to 4-channel simultaneous measurement (optional)


Titration control:             Proportional polarization potential comparator


Detection:                       Constant current polarization potential


Measuring range:           0.1mg - 999.999mg H2O


Stirring method:             Magnetic stirrer


Titration flask:                Open vessel with lid, Capacity 150mL


Display:                          8.4-inch color LCD touch screen


File memory:                  Sample parameters: 99
                                       Factor parameters: 99
                                       Schedules: 99
                                       Results: 9,999


Calculation:                    Concentration calculation, statistical calculation,
                                       recalculation, reanalysis of titration curve


Buret:                             Syringe type
                                      Volume: 10mL (option 25mL)
                                      Dosing speed: 1mL/ 1.5sec
                                      Aspiration speed: 1mL/ 1.5sec
                                      Accuracy: ±0.02mL (10mL syringe)


Printer:                          Option, thermal or dot impact


External input and output:
                                      Electric balance: Automatic input of weight
                                      USB: 4 ports
                                      LAN: 1 port


Additional functions:    Data integrity (GLP/GMP support), detection
                                      electrode conditioning


Bromine mode:             Bromine Index and Bromine Number


Operating conditions:   Temperature: 15-40oC
                                      Relative humidity: below 85% ; do not condense.


Power supply:                AC 100/115/230/240V (50/60 Hz) 80VA


Dimensions:                  CA-310MC: Approx. 245(W)× 160(D)× 215(H) mm
                                      CA-310STR: Approx. 120(W)× 340(D)× 135(H) mm
                                      CA-310BRT: Approx. 110(W)× 320(D)× 275(H) mm


Weight:                          CA-310MC: Approx. 2.0kg
                                      CA-310STR: Approx. 2.5kg
                                      CA-310BRT: Approx. 3.5kg


 

 
 Options

Sample Boat TypeVA-300
model VA-300

Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples

Heating temperature: 50~300oC
Heater: Transparent electro-conductive glass 150W
Sample size: Up to 10g
Measuring range: From 5ppm (when used in combination with CA-300)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Dimensions, Weight: approx. 323(W)× 170(D)× 260(H) mm, 4kg


Disposable Vial TypeVA-230
model VA-230

Enables easy measurement using disposable vials. Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples

Heating temperature: 70~300oC
Heater: Aluminum block heater 60W×2
Sample size: Up to 10g and 2.5ml volume, vial volume:10ml
Measuring range: From 30ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 300(W)× 135(D)× 220(H) mm, 3.5kg


VA-24VSAutosamplers and Vaporizers
model VA-236S

Automatic and consecutive measurements up to 33 samples(Vials).Carrier gas is controlled by a mass flow controller, realizing a stable flow rate regardless of the gas pressure.
Platics, rubbers, food products, medical products, inorganic salts, powders, and other solid samples can be measured. Certain oil samples can also be measured using a special needle.

Heating temperature: 70~300oC
Gas flow: 0 to 500ml/min(set from moisture meter)
Carrier gas: Nitrogen gas, <0.01 % moisture
Carrier control: Mass flow controller
Vials(10ml): Total 36, including purge vials
Sample size: <10g and < 2.5ml in volume(solids) < 5ml(oils)
Power supply: AC 100-120V, 200VA/AC220-240V, 250VA
Dimensions: 370(W)*560(D)*400(H) mm
Weight: 18kg


Autosamplers and Vaporizers
model VG-200
VA-122
Ideal injector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.

Applicable gases: Propane. Butane,other liquefide gases(Up to 5 different gas factors can be set)
Injection rate: 100 to 600ml/min
Injection volume: 1 to 99L
Heater temperature: 40 to 90℃
Power supply: AC100-120V, 40VA/ AC220-240V, 20VA
Dimensions: 150(W)*350(D)*270(H) mm
Weight: 6 kg


High TemperaturesVA-121
model VA-121

Iron ore, clay, metal oxides, inorganic salts

Heating temperature: 250~1000oC
Heater: Electric Furnace (Kanthal wire) 800W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
     Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 420(W)× 260(D)× 420(H) mm, 15.5kg


High/Low TemperaturesVA-122
model VA-122

Enables measurement of ancillary moisture. Iron ore, clay, welding rods, metal oxides, inorganic salts

Heating temperature: 70~300oC, 250~1000oC
Heater: Electric Furnace (Kanthal wire) 1000W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
     Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 690(W)× 290(D)× 410(H) mm, 20kg


 
Notation



No.103, Sec. 3, Tianjin Rd., Beitun Dist., Taichung City 40666, Taiwan Tel:+886-4-22994269 Fax:+886-4-22371824 Free Call :0800-286186   
E-mail:sn.st@msa.hinet.net       2013-2019 © South&North International Co., Ltd. All Rights Reserved      Designed by Chyue