Karl-Fischer Moisture Meter
AQUAMICRON
AQUAMICRON
Karl-Fischer Moisture Meter
Automatic Titration Model
Total Sulfur Analyzer
Total Chlorine Analyzer
Total Nitrogen Analyzer
Total Sulfur/Chlorine Analyzer
Total Sulfur/Nitrogen Analyzer
Total Sulfur/Chlorine/Nitrogen Analyzer
Adsorbable Organic Halogen Analyzer
Total Organic Carbon Analyzer
Automatic Quick Furnace model
Automatic Quick Furnace model
Resistivity Meter Series
Resistivity Meter Series
Resistivity Meter Series
Powder Resistivity Measuring System
Measures Resistivity
Integrating-Sphere Turbid Meter
Thickness Tester model TH-11 with optional printer
Special electrolyte device
MX-50(A&D)
Precision Oven
Differential Scanning Calorimeter
Transient Plane Source
  Classification >>  Total Sulfur Analyzer >> Trace Sulfur Analyzer >> 
    Related Product >> 
  Trace Sulfur Analyzer model TS-100V Frequency 18124
Model No: TS-100V
Product Name: Trace Sulfur Analyzer model TS-100V
Maker: Mitsubishi Chemical Analytech
Distributor: South&North International Co., Ltd.
RelateDate

Specification
TS-100V (Vertical Furnace Combustion Type)
The combination of the Ultra Violet Fluorescence method as a sulfur detector and the vertical furnace combustion system using Oxygen control (patent pending) realize more defined trace Sulfur measurements for Petroleum, Petrochemical and Fuels.
 
TS-100V
 
Features

Dry Method: The UVFL detection needs no wet chemical reagents.
Highly sensitive analysis: Oxygen controlled combustion system realized the ppb order Sulfur measurement.
Rapid measurement: Vertical Furnace Combustion cuts down the heating and cooling time.
Simultaneous Nitrogen and Sulfur measurements: Nitrogen detector (option) can be attached easily.
Standard method: This analysis is used for the certified method indicated below.

 

Sulfur ASTM D5453/ Oxygen digestion and UVFL Nitrogen ASTM D4629, D5176, D5762, D6069

 

 TS-100V Specifications
《 Sulfur measurement (Standard), Nitrogen measurement (option)》


Samples :  Liquid and gaseous samples

Analytical method :  Sulfur meas.: Oxidative pyrolysis-ultraviolet fluorescence method
Nitrogen meas.: Oxidative pyrolysis-chemiluminescence method

Sample introduction method:  Directly introduced using microsyringe

Sample size:  Liquid samples: 5-200μl*1 , Gaseous sample: 1-10ml*2

Measuring range:  20ppb-10,000 ppm

Measurement time:  5-10 min./ measurement

Furnace temperature:  Max. 1,100oC

Gas requirements :  Argon  (purity:99.98% or more, 0.2-0.4MPa)
Oxygen( purity:99.7% or more, 0.2-0.4MPa)

Dimensions, weight:  Main Unit: approx. 500W×400D×500H mm, 35kg
Sulfur detector: approx. 260 W×360D×430H mm, 19kg
Controller: approx. 260W×310D×110H mm, 5.5kg

*1: The optional ASC-150L or CRI-100V is required when measuring liquid samples. Optional microsyringe is also required when measuring over 50μl samples.
*2: The optional Gas Injector is required when measuring gaseous samples.

 
Options

Liquid Auto Sampler
model ASC-150L

Liquid Auto Sampler model ASC-150L is an auto-sampler in which liquid samples (max.50 battles) are injected automatically.

ASC-150L

Syringe: 50μl microsyringe (option: 25/100/250μl)
Sample Vial: 6ml/50 places
Rinse Vial: 28ml/2 places
Sample Injection Times: 1-30 times/1 vial
Rinsing Function: 0-5 times
Dimensions, Weight: approx. 460W×320D×470H mm, 16kg


Nitrogen DetectorND-100
model ND-100

Connecting this Nitrogen detector to the TS-100V system allows measurement of total Nitrogen.

Detection method: Oxidation decomposition, chemluminescence
Dimensions, Weight: approx. 260W×360D×430Hmm , 17kg


Constant Rate Injector CRI-100H
model CRI-100V

Non-aqueous samples are injected at a constant rate using a microsyringe.

Syringe: 50μl microsyringe (option: 25/100/250μl)
Injection rate: 0.2-1.3μl/sec variable
Dimensions, Weight: approx. 250W×150D×286Hmm, 7kg


Gas Injector GI-100
model GI-100

This system is used for analysis of gaseous samples.

Liquid standard sample Size: max. 20μl (gas-tight microsyringe)
Gaseous standard sample Size: max. 10μl (gas-tight microsyringe)
Gas requirements: Argon (purity: 99.98% or more)
Dimensions, Weight: approx. 120W×250D×235Hmm, 4kg


 
 
Notation